# CAPA format: corrective and preventive action report in Excel and Word

> A CAPA report takes one problem, such as a deviation, a market complaint or an audit finding, from the first fix to proof that it will not happen again. Fill this one in on the page, or download it in Excel or Word.

Page: https://www.emplotec.com/templates/capa-format · Updated: 2026-11-27

Market: India

- Correction, CA and PA kept apart
- 5-why root cause and risk score
- Effectiveness check before closure
- Excel with formulas, Word, A4 PDF

## Download

- Excel: https://www.emplotec.com/downloads/capa-format.xlsx
- Word: https://www.emplotec.com/downloads/capa-format.docx
- PDF (blank, A4): https://www.emplotec.com/downloads/capa-format.pdf
- Fill it in online: https://www.emplotec.com/templates/capa-format

## What the format contains

- Title: Corrective and preventive action (CAPA) (Quality assurance). Copy line: QA copy
- Issuer block: Name and address, Name and address
- Fields: CAPA no., Date opened, Source, Source reference, Product, Batch nos., Department and line, Raised by, Risk class, Change control, Target closure, CAPA owner
- Problem statement (what, where, when, how many, how found): A pharmacist in Madurai reported one blister strip of batch MTB26114 with an empty pocket (9 tablets in a 10-tablet strip). The control sample of the batch had no defect. The batch was packed on blister line BL-02 on 14-10-2026; the camera inspection system did not reject the strip.
- Immediate correction and containment: 07-11-2026: remaining stock of MTB26114 in the warehouse (1,840 shippers) put on QA hold and inspected strip by strip; 3 more empty-pocket strips found and destroyed. BL-02 stopped until the camera was checked.
- Impact assessment (other batches, products, lines, markets): Six batches were packed on BL-02 since the format change on 02-10-2026. Control samples and warehouse stock of all six inspected: defects found only in MTB26114. Lines BL-01 and BL-03 use the same camera model and were checked: settings correct.
- Root cause: 5 whys, columns: Why, Question, Answer and evidence
- Root cause: Method: the line-clearance SOP does not require a camera challenge test after a format change, so a parameter reset went undetected. Category: method (6M).
- Risk score (severity x occurrence x detection, 1 to 10 each): Severity, Occurrence, Detection, Risk priority number, before CAPA, Occurrence after CAPA, Detection after CAPA, Risk priority number, after CAPA
- Actions, columns: No., CA or PA, Action, Owner, Target, Done, Evidence
- Effectiveness check (criteria, period, result): Criteria: all start-up and shift challenge tests on BL-01 to BL-03 pass, and no empty-pocket complaint, over the next 20 batches or three months, whichever is later. Review due 28-02-2027.
- Fields: Effective?, Closed on, Reported in product quality review
- Signatures: Raised by, CAPA owner, Head, quality assurance (approval and closure)

## What CAPA means, and what the format must show

CAPA stands for corrective and preventive action. A correction fixes the problem in front of you (inspect and destroy the bad strips). A corrective action removes the cause, so the same problem does not happen again (restore and lock the camera settings). A preventive action removes the cause of a problem that has not happened yet, or stops it spreading to other lines and products (a challenge test on every line after every format change). A CAPA format keeps the three apart, because auditors check that a CAPA did more than the correction.

| Part | What it records |
| --- | --- |
| Header | CAPA number, date, source and its reference, product, batch, department, owner, risk class, target date, linked change control |
| Problem statement | What happened, where, when, how many and how it was found, in facts, not conclusions |
| Correction and containment | What was done straight away to protect the patient or customer |
| Impact assessment | Other batches, products, lines, sites and markets that could be affected, and what was checked |
| Root cause | The investigation (5 whys, fishbone) and the cause it reached, with evidence |
| Risk | Severity, occurrence and detection before and after the CAPA |
| Actions | Each corrective and preventive action with an owner, a target date, a done date and evidence |
| Effectiveness check | Measurable criteria, the period, and the result before closure |
| Approval | Owner and the head of QA, who closes it |

## CAPA under Schedule M, ICH Q10 and ISO 9001

**Medical device makers follow the quality management system in the Fifth Schedule of the Medical Devices Rules, 2017, which has its own corrective and preventive action clauses.**

| Where | What it expects |
| --- | --- |
| Revised Schedule M, Drugs Rules, 1945 (notified December 2023) | A pharmaceutical quality system in which deviations, complaints and failures are investigated to their root cause, CAPA is taken and its effectiveness checked, and CAPAs are reviewed in the annual product quality review. Units with turnover up to ₹250 crore had until 31 December 2025 to comply |
| ICH Q10, section 3.2.2 | A CAPA system fed by complaints, rejections, non-conformances, recalls, deviations, audits, inspection findings and trends, with the depth of investigation matched to the risk |
| ICH Q9 | Quality risk management: the risk score decides how deep the investigation goes and how fast the actions must be |
| ISO 9001:2015, clause 10.2 | React to the nonconformity, find its cause, check whether similar ones exist or could occur, act, review the effectiveness, and keep documented information |
| US FDA, 21 CFR 211.192 (for exporters) | Any unexplained discrepancy or batch failure is thoroughly investigated, extended to other batches that may be affected, and recorded with conclusions and follow-up |

## What should trigger a CAPA

- Deviations in manufacturing, packing or testing, once investigated.
- Out-of-specification and out-of-trend results confirmed as true failures.
- Market complaints, returns and recalls.
- Observations from regulatory inspections, customer audits and self-inspection.
- Trends in the product quality review, stability data or environmental monitoring.
- Supplier non-conformances (often raised to the supplier as a corrective action request).

Not every deviation needs a full CAPA. A minor, one-off event with a clear cause may be closed with a correction, if the investigation records why no CAPA was needed. Repeats of the same minor deviation are themselves a reason for a CAPA.

## How to fill in the CAPA format

1. Open the CAPA from its source (complaint, deviation, audit) and copy the reference, product and batch into the header.
2. Write the problem statement in facts: what, where, when, how many, how found. Leave the cause out of it.
3. Record the correction and containment done straight away, with dates and quantities.
4. Assess the impact: which other batches, lines, products and markets could be affected, and what you checked.
5. Investigate the root cause with 5 whys or a fishbone (man, machine, method, material, measurement, environment), and keep the evidence.
6. Score the risk. The calculation above multiplies severity, occurrence and detection; 6 x 4 x 7 gives 168 before the CAPA and 6 x 2 x 2 gives 24 after.
7. List each corrective and preventive action with one owner and a target date. Link any SOP, equipment or document change to change control.
8. Set the effectiveness check before closing: measurable criteria and a period. QA closes the CAPA only when the result is in.

## CAPA, deviation, NCR and 8D compared

| Document | What it records | Used mostly in |
| --- | --- | --- |
| Deviation | A departure from an approved instruction, procedure or specification, and its investigation | Pharma and food |
| NCR (non-conformance report) | Material or product that does not meet its requirement, and what is done with it (rework, scrap, use as is) | Engineering and automotive |
| CAPA | The cause behind one or more deviations, NCRs or complaints, and the actions that remove it | Every regulated industry |
| 8D report | A team's eight-discipline answer to a customer complaint, from containment to recognising the team | Automotive suppliers |

## Common mistakes in CAPA reports

- 'Operator error' as the root cause, with 'operator retrained' as the only action. Ask why the system let the error through.
- The correction written as the corrective action, so nothing changes.
- No impact assessment, so the same defect sits in other batches or lines.
- Actions with no owner or date, or a team as the owner.
- Closed the day the actions are done, with no effectiveness check.
- SOP and equipment changes made without change control.
- Target dates extended again and again with no reason recorded.

## Or let the CAPA open itself from the complaint.

In Emplotec Quality a complaint, deviation or audit finding opens an NCR or a CAPA with its source attached; root cause, actions and the effectiveness check sit on the same record, and the stock it affects stays held in QC until released.

- NCR, CAPA with root cause and an effectiveness check, and 8D for customer complaints.
- Stock held in QC until released, and GMP batch release against the batch manufacturing record.
- Controlled documents with acknowledgement, so a revised SOP reaches every operator who must read it.
- Corrective-action requests to suppliers on the vendor portal, feeding vendor rating; CAPAs reviewed in internal audits and management review.

Read more: [Emplotec Quality](https://www.emplotec.com/erp/quality.md)

## Questions and answers

### What is the full form of CAPA?

Corrective and preventive action: the actions taken to remove the cause of a problem that has happened (corrective) and of one that could happen (preventive).

### What is the difference between correction and corrective action?

A correction fixes the defect found, such as reworking or destroying bad units. A corrective action removes the cause so the defect does not recur.

### Is CAPA required under Schedule M?

Yes. Revised Schedule M asks for a pharmaceutical quality system in which deviations, complaints and failures are investigated, CAPA is taken and checked for effectiveness, and CAPAs are reviewed in the product quality review.

### How long should a CAPA take to close?

No law sets a number. Most companies set target dates by risk class in their CAPA SOP, and record a reason for every extension. The CAPA closes only after the effectiveness check.

### What is an effectiveness check in CAPA?

A planned review, with measurable criteria and a period, that shows the problem has not recurred, for example no repeat complaint and all challenge tests passing over 20 batches.

### Can 'operator error' be a root cause?

Auditors rarely accept it alone. Ask why the process let the error happen or go undetected; the answer is usually a method, training or design cause that a CAPA can fix.

## Sources

- [CDSCO: Drugs Rules, 1945, revised Schedule M (good manufacturing practices), notified December 2023](https://cdsco.gov.in/)
- [ICH Q10, Pharmaceutical Quality System, section 3.2.2 (CAPA system)](https://www.ich.org/page/quality-guidelines)
- [ICH Q9(R1), Quality Risk Management](https://www.ich.org/page/quality-guidelines)
- [Bureau of Indian Standards: IS/ISO 9001:2015, clause 10.2 (nonconformity and corrective action)](https://www.bis.gov.in/)
- [US FDA: 21 CFR 211.192, production record review](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.192)

## Related

- [/erp/quality](https://www.emplotec.com/erp/quality.md)
- [/templates/control-plan-format](https://www.emplotec.com/templates/control-plan-format.md)
- [/templates/complaint-register-format](https://www.emplotec.com/templates/complaint-register-format.md)
- [/templates/near-miss-report-format](https://www.emplotec.com/templates/near-miss-report-format.md)

---

- Talk to us: https://www.emplotec.com/contact (we call back within one working day)
- Email: preethan@emplotec.com · Phone and WhatsApp: +91 93420 95081
- Evaluating an ERP? Read the brief: https://www.emplotec.com/erp/brief.md
- Every page as Markdown: https://www.emplotec.com/llms.txt
- All templates: https://www.emplotec.com/templates.md
- /erp/quality: https://www.emplotec.com/erp/quality.md
- /templates/control-plan-format: https://www.emplotec.com/templates/control-plan-format.md
- /templates/complaint-register-format: https://www.emplotec.com/templates/complaint-register-format.md