Free templateSafety and compliance
Fire risk assessment template for the Fire Safety Order 2005
A fire risk assessment looks at what could start a fire, who would be at risk, and whether the precautions are enough. This template follows the GOV.UK five steps and records the assessment in full, as every responsible person in England and Wales must since October 2023.
- Fire Safety Order 2005, article 9
- Recorded in full (since 1 Oct 2023)
- 34-point checklist
- Risk level and action plan
Written for UK. Elsewhere:Risk assessment template UK
Last updated
Fill it in with your own details. Click any highlighted space and type, then print it or save it as a PDF, straight from this page. Nothing you type leaves your browser.
Regulatory Reform (Fire Safety) Order 2005, article 9. Recorded in full, with the fire safety arrangements.
The premises
The people
Checklist: Y (yes), N (no, action needed), N/A
| Ref. | Area | Question | Y/N/NA | Findings |
|---|---|---|---|---|
Action plan
| No. | Ref. | Action | Priority | By whom | By when | Done |
|---|---|---|---|---|---|---|
Fire safety arrangements (article 11)
Regulatory Reform (Fire Safety) Order 2005, article 9. Recorded in full, with the fire safety arrangements.
The premises
The people
Checklist: Y (yes), N (no, action needed), N/A
| Ref. | Area | Question | Y/N/NA | Findings |
|---|---|---|---|---|
Action plan
| No. | Ref. | Action | Priority | By whom | By when | Done |
|---|---|---|---|---|---|---|
Fire safety arrangements (article 11)
Managed by the site manager. Weekly alarm test (Mondays, 09:00), monthly emergency lighting checks and quarterly fire door checks logged in the fire log book. Alarm and emergency lighting serviced six-monthly, extinguishers annually. Two fire wardens per shift. Assembly point: car park, north side.
Example entries. Go back to blank to fill in your own.
What a fire risk assessment is, and who must do one
A fire risk assessment is a careful look at your premises and the people who use them: what could start a fire, what would burn, who would be at risk, and whether the precautions you have are enough to keep them safe. Under article 9 of the Regulatory Reform (Fire Safety) Order 2005 (the Fire Safety Order), it must be suitable and sufficient, and it applies to almost every non-domestic premises in England and Wales, and to the common parts of blocks of flats.
The duty falls on the responsible person (article 3): the employer, for a workplace under their control; otherwise the person who has control of the premises, such as the occupier or the owner. Where several people share responsibility, for example a tenant and a landlord, each must do their part and cooperate (article 22).
The five steps of a fire risk assessment
GOV.UK's fire safety guidance sets out five steps. This template follows them in order:
| Step | What you do | On the template |
|---|---|---|
| 1. Identify fire hazards | Sources of ignition (electrics, hot work, smoking, heaters, batteries, arson), fuel (waste, stock, flammable liquids, gases) and oxygen (ventilation, oxidisers, cylinders) | Checklist 1 and 2 |
| 2. Identify people at risk | Everyone on site, and especially people who sleep there, people with disabilities, lone or remote workers, young persons, visitors and contractors | The people |
| 3. Evaluate, remove, reduce and protect from risk | Remove or reduce the hazards, then check escape routes, fire doors, detection and alarm, emergency lighting, signs, firefighting equipment and compartmentation | Checklist 3 to 5, risk level |
| 4. Record, plan, inform, instruct and train | Record the assessment in full and your fire safety arrangements, write an emergency plan, tell staff and others, and train them | Checklist 6, action plan, arrangements |
| 5. Review | Review regularly and whenever something changes: layout, use, occupants, processes, or after a fire or near miss | Review by |
Rating the fire risk level
Most UK fire risk assessors rate the overall risk on a five-level scale, from trivial to intolerable, the scale used in the example assessment in PAS 79, the BSI code of practice for fire risk assessment. First judge the likelihood of a fire starting (low, medium or high) from the hazards and how well they are controlled. Then judge the consequences if one did start (slight, moderate or extreme harm) from the people at risk and the fire protection in place.
| Likelihood of fire | Slight harm | Moderate harm | Extreme harm |
|---|---|---|---|
| Low | Trivial | Tolerable | Moderate |
| Medium | Tolerable | Moderate | Substantial |
| High | Moderate | Substantial | Intolerable |
| Risk level | Action |
|---|---|
| Trivial | No action needed |
| Tolerable | No major additional controls; look for low-cost improvements |
| Moderate | Make the efforts needed to reduce the risk, within a defined time |
| Substantial | Considerable resources may be needed; act urgently |
| Intolerable | Do not start or continue the activity until the risk is reduced |
PAS 79 and choosing an assessor
PAS 79-1:2020 (premises other than housing) and PAS 79-2:2020 (housing) are BSI's codes of practice for fire risk assessment. They aren't law, but they set out the method most professional assessors use and what the record should contain: the premises and the people, the fire hazards and how they are controlled, the fire protection measures, the management of fire safety, the risk level, and an action plan. This template follows the same order.
A small, simple workplace can often be assessed by the responsible person using GOV.UK's guidance for that type of premises. For larger or complex premises, sleeping accommodation, or blocks of flats, appoint a competent fire risk assessor. The Fire Sector Federation publishes a guide to choosing a competent fire risk assessor, and several professional bodies keep registers of assessors.
Blocks of flats: the Fire Safety (England) Regulations 2022
The Fire Safety Act 2021 made clear that the Fire Safety Order covers the structure, external walls (including balconies and windows) and flat entrance doors of buildings with two or more sets of domestic premises. The Fire Safety (England) Regulations 2022, in force since 23 January 2023, add duties by building height:
| Building | Duties |
|---|---|
| Two or more sets of domestic premises | Give residents fire safety instructions and information about the importance of fire doors |
| Over 11 m tall | Check communal fire doors at least every 3 months, and use best endeavours to check flat entrance doors at least every 12 months |
| High-rise (18 m or 7 storeys and over) | Secure information box, wayfinding signage, floor and building plans and external wall information to the fire and rescue service, monthly checks of lifts for firefighters and key fire safety equipment, with faults reported |
Scotland and Northern Ireland
The Fire Safety Order applies in England and Wales. In Scotland, the duty to carry out a fire safety risk assessment comes from Part 3 of the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006, with guidance from the Scottish Government. In Northern Ireland, it comes from the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010. The method in this template works in both, but the legal references differ.
Reviews and enforcement
Review the assessment regularly, and at once if there is reason to think it is no longer valid or if the premises, the work or the people change significantly (article 9(3)). Many responsible persons review at least once a year and after any fire, near miss or alteration.
Fire and rescue authorities enforce the Order. They can issue alteration, enforcement and prohibition notices, and offences can be tried in the Crown Court, with an unlimited fine and up to two years' imprisonment (articles 32 and 33).
Common fire risk assessment mistakes
- Recording only the significant findings. Since October 2023, the whole assessment must be recorded.
- A copied generic template that doesn't describe your building, your processes or your people.
- Forgetting hot work, battery charging and waste skips, three common causes of workplace fires.
- No PEEP for someone who can't use the stairs unaided.
- Fire doors that are wedged open, don't latch, or have damaged seals.
- Actions with no owner or date, so the same findings appear at the next review.
Emplotec Quality
Or run the checks and the actions from one place.
In Emplotec, the fire risk assessment sits with your other risk assessments and safety inspections, every finding becomes an action with an owner and a date, and the routine fire checks run on the phone.
- Hazard identification and risk assessments, safety inspections and toolbox talks in one register, with incidents and near misses beside them.
- Weekly alarm tests, monthly emergency lighting checks and fire door checks run as mobile checklists.
- With Assets & Maintenance, alarm, emergency lighting and extinguisher servicing are preventive maintenance plans, and hot work runs under a permit to work.
- Ask Emplotec which fire actions are past their date, and it lists them with their owners.
- Fire alarm test, call point 7Mon 09:00
- Escape routes walk roundMon
- Emergency lighting, monthlyDue Fri
Emplotec Welding is booked in bay 3 on Thursday, and the hot work permit action is still open. Draft the permit for the site manager to approve before the job starts?
FRA-2026-01WO-26-1184The site's fire safety page, with three high-priority actions from the latest assessment. Example companies, people and figures.
Questions people ask about the fire risk assessment format
Is a fire risk assessment a legal requirement?
Yes. Under article 9 of the Regulatory Reform (Fire Safety) Order 2005, the responsible person for almost any non-domestic premises in England and Wales, including the common parts of blocks of flats, must carry out a suitable and sufficient fire risk assessment and keep it under review.
Does a fire risk assessment have to be written down?
Yes. Since 1 October 2023, every responsible person in England and Wales must record the whole fire risk assessment in writing, regardless of the number of employees, along with the fire safety arrangements and the name of anyone who helped carry it out. Before that, only premises with five or more employees, a licence or an alterations notice had to record the significant findings.
Can I do my own fire risk assessment?
For small, simple premises, often yes, using GOV.UK's guidance for your type of building. If you can't be confident of doing it properly, or the premises are large, complex, have people sleeping in them or are a block of flats, appoint a competent fire risk assessor. Anyone you appoint to help must be competent.
How often should a fire risk assessment be reviewed?
The law says regularly, and whenever there is reason to think it is no longer valid or something significant changes: the layout, the use, the processes or the people. Many responsible persons review at least once a year and after any fire or near miss.
What are the five steps of a fire risk assessment?
Identify the fire hazards; identify the people at risk; evaluate, remove, reduce and protect from risk; record, plan, inform, instruct and train; and review. This template follows those steps in order.
What is PAS 79?
PAS 79 is the BSI code of practice for fire risk assessment: PAS 79-1:2020 covers premises other than housing and PAS 79-2:2020 covers housing. It isn't law, but most professional assessors follow its method, and most rate risk on a five-level scale from trivial to intolerable.
What happens if I don't have a fire risk assessment?
The fire and rescue authority can issue an enforcement or prohibition notice. Serious offences under the Fire Safety Order can lead to an unlimited fine and up to two years in prison.
Sources
- Regulatory Reform (Fire Safety) Order 2005 (SI 2005/1541)https://www.legislation.gov.uk/uksi/2005/1541/contents
- GOV.UK: Fire safety risk assessment, 5-step checklisthttps://www.gov.uk/government/publications/fire-safety-risk-assessment-5-step-checklist
- GOV.UK: Fire safety responsibilities under section 156 of the Building Safety Act 2022https://www.gov.uk/government/publications/check-your-fire-safety-responsibilities-under-section-156-of-the-building-safety-act-2022/fire-safety-responsibilities-under-section-156-of-the-building-safety-act-2022
- Building Safety Act 2022, section 156https://www.legislation.gov.uk/ukpga/2022/30/section/156
- Fire Safety (England) Regulations 2022 (SI 2022/547)https://www.legislation.gov.uk/uksi/2022/547/contents
- GOV.UK: Fire risk assessment guides for different types of premiseshttps://www.gov.uk/government/collections/fire-safety-law-and-guidance-documents-for-business
- BSI: PAS 79-1:2020, Fire risk assessment, premises other than housinghttps://knowledge.bsigroup.com/products/fire-risk-assessment-premises-other-than-housing-code-of-practice
- Welsh Government: Fire safety responsibilities under section 156https://gov.wales/fire-safety-responsibilities-under-section-156-building-safety-act-2022-guidance-html
Related
Stop typing fire risk assessments by hand.
Tell us how your business runs. We'll show you Emplotec raising this from the work itself, on your own numbers, and reply within one working day.