Free templateProduction and quality

CAPA template: a corrective and preventive action form with an effectiveness check

A CAPA record takes a problem from the first report to proof that the fix worked: containment, root cause, corrective and preventive actions, verification, and an effectiveness check with numbers. This template works the effectiveness check out for you.

  • FDA QMSR (ISO 13485 8.5.2, 8.5.3)
  • 21 CFR 211.192 and ISO 9001 10.2
  • Effectiveness check in defects per million
  • Excel with formulas, Word, PDF

Written for US. Elsewhere:CAPA format India

Last updated

Fill it in with your own details. Click any highlighted space and type, then print it or save it as a PDF, straight from this page. Nothing you type leaves your browser.

Corrective and preventive action (CAPA)

Corrective or preventive action

Problem statement (what, where, when, how many, how found)

Correction and containment

No.ActionOwnerDoneResult

Investigation and root cause (method: 5 whys and fishbone, with test data)

Corrective and preventive actions

No.ActionTypeOwnerDueVerified or validated

Effectiveness check (defects per million units)

Units before
Defects before
Defects per million before
Units after
Defects after
Defects per million after
Reduction (%)

Effectiveness result and closure

CAPA owner
Quality manager
Management representative

What a CAPA is

CAPA stands for corrective and preventive action. It is the quality system's way of making sure a problem is fixed at its cause and doesn't come back, and of acting on problems that haven't happened yet. A CAPA record (or corrective action report) follows one problem from the trigger to closure, so an auditor or an FDA investigator can see what was found, what was done and the evidence that it worked.

TermWhat it is (ISO 9000:2015)Example from the template
CorrectionAction to eliminate a detected nonconformityScrapping the 11 leaking sets found in the held stock
Corrective actionAction to eliminate the cause of a nonconformity and prevent it recurringRestoring the 4-hour cure with an interlock
Preventive actionAction to eliminate the cause of a potential nonconformity and prevent it occurringChecking other solvent-bonded products for the same change

Triggers include customer complaints, nonconformances, deviations, audit findings, out-of-specification results, returns, trends in process data and management review. Not every nonconformance needs a CAPA: decide by risk, and record why when you don't open one.

What FDA and ISO require of a CAPA

Where any ISO 13485 clause conflicts with the FD&C Act or FDA's regulations, FDA's rules control. FDA retired its QSIT inspection approach with the QMSR; investigators still review CAPA records closely.
RuleWho it applies toWhat it asks for
FDA Quality Management System Regulation (21 CFR 820), from 2 February 2026Medical device manufacturers selling in the USPart 820 now incorporates ISO 13485:2016 by reference. CAPA requirements, formerly 21 CFR 820.100, are in clauses 8.5.2 (corrective action) and 8.5.3 (preventive action)
ISO 13485:2016, 8.5.2 and 8.5.3Device makers (and their certified suppliers) worldwideReview the nonconformity, determine the cause, evaluate and take action without undue delay, verify the action doesn't adversely affect meeting requirements or the safety and performance of the device, review its effectiveness, and keep records
21 CFR 211.192Drug manufacturers (cGMP)Any unexplained discrepancy or failure of a batch to meet specifications is thoroughly investigated, extended to other batches that may be affected, with a written record of conclusions and follow-up
ISO 9001:2015, 10.2Any certified organizationReact to the nonconformity, evaluate the need for action on its cause, implement it, review effectiveness, update risks and opportunities, change the QMS if needed, and keep documented information

What to include in a CAPA form

SectionWhat to write
HeaderCAPA number, date opened, source with its reference, corrective or preventive, product or process, risk, owner and target date.
Problem statementWhat, where, when, how many and how it was found, with numbers. Describe the failure, not a guess at the cause.
Correction and containmentWhat was done straight away to protect customers: quarantine, sorting, field action assessment.
Investigation and root causeThe method (5 whys, fishbone, fault tree, data analysis), the evidence, the root cause, and why the problem escaped detection.
ActionsEach action with its type, owner and due date, and the verification or validation done before it was put in place.
Effectiveness checkThe measure, the target, the period and the result, decided before you implement the fix.
ClosureThe result, documents updated (procedures, risk file, PFMEA, training) and approvals.

How to prove a CAPA was effective

Closing the actions doesn't prove the problem is gone. Before implementing, set a measure that would show the failure, a target and a period long enough to see it. In the example the measure is leak failures per million units shipped:

Reduction = (750 - 38.46) / 750 x 100 = 94.87%, against a target of 90% or more. The template works this out from the four inputs.
BeforeAfter
Units shipped48,00052,000
Leak failures362
Per million (failures / units x 1,000,000)75038.46

Compare rates, not counts, because the volumes differ. Where failures are rare, a longer period or a larger sample is needed before zero means anything. If the target isn't met, the CAPA stays open and the investigation goes back to root cause.

How to fill in the CAPA template

  1. Open the CAPA with its source reference and a risk rating; high risk problems get containment the same day.
  2. Write the problem statement with numbers before anyone suggests a cause.
  3. Record correction and containment, including the decision on field action and who made it.
  4. Investigate with data. Find the cause of the failure and the reason it wasn't caught.
  5. List actions against each cause, with owners and dates. Verify or validate each before it goes live.
  6. Set the effectiveness measure, target and period, then enter the before and after figures; the template works out the rates and the reduction.
  7. Update the procedures, risk file and training, get the approvals, and take open CAPAs to management review.

Common CAPA findings in audits and inspections

  • Root cause written as "operator error" with retraining as the only action.
  • CAPAs closed when the actions are done, with no effectiveness check.
  • Problems that recur under new CAPA numbers because nobody trended them.
  • Changes put in place without verification or validation.
  • Investigations limited to the batch or lot in hand, not the other products or lots that could be affected.
  • CAPAs open for months with no interim containment.

Emplotec Quality

Or let the CAPA open itself from the complaint.

In Emplotec Quality a complaint, deviation or audit finding opens an NCR or a CAPA with its source attached; root cause, actions and the effectiveness check sit on the same record, and the stock it affects stays held in QC until released.

  • NCR, CAPA with root cause and an effectiveness check, and 8D for customer complaints.
  • Stock held in QC until released, so a quarantine is a status, not a sign on a pallet.
  • Controlled documents with acknowledgement, so a revised procedure reaches everyone who must read it.
  • Corrective-action requests to suppliers on the vendor portal, feeding vendor rating; CAPAs reviewed in internal audits and management review.
CAPAMinneapolis plant · November 2026
OpenEffectiveness checkOverdueClosedNew CAPAExport register
EmplotecCAPA-26-031 met its target: 750 to 38.46 failures per million, a 94.87% cut. Ready to close.
Open CAPAs7
In effectiveness check3
Overdue actions2
Median days to close96
Open CAPAs
CAPAProblemSourceActionsStatus
CAPA-26-031Luer bond leaks, EX-30Bonding cell 2Complaints4 of 4Target met
CAPA-26-034Label print smudgePackaging line 1Deviation1 of 3Overdue
CAPA-26-036Supplier tubing OD driftIncomingNCR2 of 3In progress
Recent
  • S. Lindgren entered November figures for CAPA-26-031
  • Supplier portal Northbrook Tubing answered the corrective-action request
  • Document control QP-7.5 rev. F acknowledged by 41 of 41

Emplotec Two other CAPAs this year trace to process changes made without validation. Open a preventive action on change control across all cells?

CAPA-26-031CAPA-26-019
Open preventive action

The CAPA register, with CAPA-26-031 in its effectiveness check and two others waiting on actions. Example companies, people and figures.

Questions people ask about the CAPA format

What should a CAPA form include?

The CAPA number, source, type, product or process, risk, owner and dates; a problem statement with numbers; correction and containment; the investigation and root cause; corrective and preventive actions with owners, dates and verification; an effectiveness check with a measure, target and result; and closure approvals.

What is the difference between a correction, a corrective action and a preventive action?

A correction fixes the nonconformity you found (scrap or rework the bad parts). A corrective action removes its cause so it doesn't recur. A preventive action removes the cause of a problem that hasn't happened yet, often found by looking at similar products or processes.

Is 21 CFR 820.100 still in force?

No. Since the Quality Management System Regulation took effect on 2 February 2026, 21 CFR part 820 incorporates ISO 13485:2016 by reference, and CAPA requirements are in its clauses 8.5.2 and 8.5.3. Where ISO 13485 conflicts with the FD&C Act or FDA's regulations, FDA's rules control.

How do you verify the effectiveness of a CAPA?

Set a measure, a target and a period before you implement the fix, then compare the rate before and after. In this template's example, leak failures fell from 750 to 38.46 per million units, a 94.87% cut against a 90% target, so the CAPA was effective.

What is a corrective action report?

Another name for the corrective action part of a CAPA: the record of a nonconformity, its root cause, the action taken and the evidence it worked. A supplier corrective action request (SCAR) asks a supplier to complete the same report for a problem they caused.

Does every nonconformance need a CAPA?

No. Decide by risk: an isolated, low-risk nonconformance can be corrected and trended, while a high-risk, repeated or systemic one needs a CAPA. Record the decision and the reason either way, because auditors check it.

Sources

  1. FDA: Quality Management System Regulation (QMSR)https://www.fda.gov/medical-devices/postmarket-requirements-devices/quality-management-system-regulation-qmsr
  2. FDA: QMSR frequently asked questionshttps://www.fda.gov/medical-devices/quality-management-system-regulation-qmsr/quality-management-system-regulation-frequently-asked-questions
  3. Federal Register: Medical devices; quality system regulation amendments (2 February 2024)https://www.federalregister.gov/documents/2024/02/02/2024-01709/medical-devices-quality-system-regulation-amendments
  4. 21 CFR 211.192, production record reviewhttps://www.law.cornell.edu/cfr/text/21/211.192
  5. ISO 13485:2016, medical devices: quality management systemshttps://www.iso.org/standard/59752.html
  6. ISO 9001:2015, quality management systems: requirementshttps://www.iso.org/standard/62085.html
  7. ISO 9000:2015, fundamentals and vocabularyhttps://www.iso.org/standard/45481.html

Stop typing CAPAs by hand.

Tell us how your business runs. We'll show you Emplotec raising this from the work itself, on your own numbers, and reply within one working day.

WhatsApp