Free templateProduction and quality

8D report template from D0 to D8, with containment and validation worked out

An 8D report is the eight-discipline record of solving a customer problem: team, problem, containment, root cause, corrective action, validation, prevention and closure. This template works out the containment results and the before-and-after defect rate for you.

  • D0 to D8, Ford Global 8D order
  • Occurrence and escape root causes
  • Containment and PPM worked out
  • IATF 16949 10.2.3 and 10.2.4

Written for US. Elsewhere:8D report format India

Last updated

Fill it in with your own details. Click any highlighted space and type, then print it or save it as a PDF, straight from this page. Nothing you type leaves your browser.

8D report

Status: open, contained, closed

D0: Prepare and emergency response

D1: Team

D2: Problem description, is

Is not

D3: Interim containment (100% sort of suspect stock)

LocationSuspect qtySortedRejectedReject %Sorted by
Total

Containment result

Parts sorted
Parts rejected
Reject rate in suspect stock (%)

D4: Root causes (occurrence and escape)

D5 and D6: Permanent corrective actions, verified and validated

No.ActionCauseOwnerDoneVerification

D6: Validation (defects at the customer, per million parts)

Parts shipped before
Defects before
Defects per million before
Parts shipped after
Defects after
Defects per million after

D7: Prevent recurrence

D8: Closure and recognition

Team leader
Champion
Customer quality

What an 8D report is

8D (eight disciplines) is a team method for solving a problem that has reached a customer, and the 8D report is its record. Ford built its Global 8D on the method, and automotive customers, then aerospace, electronics and medical device makers, now ask suppliers for an 8D whenever they raise a complaint. The report shows the customer that you contained the problem fast, found the real causes and changed your system so it doesn't come back.

DisciplineWhat you doWhat the customer looks for
D0 Prepare and emergency responseDecide an 8D is needed; protect the customer straight awayA quick, honest first response
D1 TeamA small cross-functional team with a champion who can approve changesThe people who know the process, not only quality
D2 Problem descriptionWhat, where, when and how many, as is and is notFacts and numbers, no causes yet
D3 Interim containmentSort, hold or replace suspect stock everywhere it could beEvery location covered, with results
D4 Root causesWhy it happened (occurrence) and why it wasn't caught (escape), verifiedCauses proven by turning them on and off
D5 Permanent corrective actionsChoose actions for each root cause and verify they workAn action per cause, including the escape
D6 Implement and validatePut the actions in place, remove containment, prove it with dataA before and after rate over a fair period
D7 Prevent recurrenceChange the systems: PFMEA, control plan, standards, similar partsThe fix spread beyond this part
D8 Closure and recognitionClose with the customer; thank the teamThe customer's acceptance

D2: describing the problem with is and is not

The is and is not comparison narrows the search before anyone guesses at a cause. For each question (what, where, when, how many) write what the problem is and what it could be but is not. Each difference points at something that changed. In the example, burrs appear on the slot but not the holes, on die D-4471-02 but not the spare die, and only in lots after 08/24: the slot punch on that die, changed on or about that date, is the place to look.

D3: containment, and how the template works it out

Containment protects the customer while you find the cause. List every place suspect stock can be: the customer's line and warehouse, in transit, your finished goods and work in process. Record the suspect quantity, how many were sorted, how many failed and who sorted. The template works out the reject rate per location and overall:

Reject % = rejected / sorted x 100. A rate that differs a lot between locations is itself a clue (for example, a lot made on a different shift).
LocationSortedRejectedReject %
Customer line1,800140.78%
In transit2,40080.33%
Finished goods6,000270.45%
Work in process1,20050.42%
Total11,400540.47%

D4: occurrence and escape root causes

An 8D needs two root causes. The occurrence cause is why the defect was made. The escape cause (Ford calls the point where it should have been caught the escape point) is why your controls let it reach the customer. Fixing only the occurrence leaves the next new defect free to escape the same way.

Verify each cause before acting on it: show the problem appears when the cause is present and disappears when it is removed. Use 5 whys, a fishbone diagram or a fault tree to find candidates, and data to confirm them. IATF 16949 clause 10.2.3 requires a documented problem-solving process covering root cause analysis, systemic corrective actions and verification of their effectiveness, and 10.2.4 asks for error-proofing where it fits.

D6: validating the fix with data

Compare the defect rate before and after over periods long enough to mean something. In the example the customer found 42 defects in 96,000 parts in the three months before the fix: 42 / 96,000 x 1,000,000 = 437.5 defects per million. In the three months after, 0 in 104,000 parts: 0 per million. The template works both out from the four inputs.

How to fill in the 8D report template

  1. Open the 8D with the customer's reference and answer D0 the same day: what you did to protect them.
  2. Name the team and the champion.
  3. Write D2 with facts only, using is and is not.
  4. Contain everywhere, record the sort results, and send the customer the D3 results; many customers want them within 24 to 48 hours.
  5. Find and verify both root causes in D4.
  6. List the corrective actions against each cause, with owners, dates and how each was verified.
  7. Enter the before and after quantities for D6 validation; the template works out the rates.
  8. Record the D7 system changes: PFMEA, control plan, standards and similar parts. Close with the customer in D8.

Common reasons customers reject an 8D

  • Root cause given as "operator error" or "human error", with retraining as the action.
  • Only the occurrence cause addressed; nothing on why the defect escaped.
  • Containment that missed stock in transit or at the customer's other plants.
  • D6 with no data, or validated over a few days.
  • D7 left blank, so the same failure appears on a sister part.
  • The report written by quality alone after the fact, not by the team.

Emplotec Quality

Or build the 8D from the records you already have.

In Emplotec the customer complaint is linked to the dispatch it came from, so the affected lots, stock locations and quantities are on the 8D from the start. The root cause, actions and the PFMEA and control plan changes stay on the part's record.

  • Customer complaints are linked to the dispatch and to Quality, with the customer's rejection debits on the same record.
  • NCR, CAPA with root cause and an effectiveness check, and 8D for customer complaints.
  • PFMEA (AIAG-VDA), control plans and PPAP packs live with the part, so D7 updates them in place.
  • Every heat and batch is traced from the gate to the customer, so containment starts from a list, not a search.
8D reportsToledo plant · 2026
OpenContainmentValidationClosedNew 8DExport
Emplotec8D-26-017: 54 rejects in 11,400 sorted (0.47%). Lots from 08/24 to 09/04 all traced to die D-4471-02.
Open 8Ds4
Customer PPM, 12 months118
Containment over 48 h0
8Ds past due1
Open 8Ds
8DCustomer and partStageDaysStatus
8D-26-017Bluegrass SeatingBR-4471, burr on slotD664Validating
8D-26-019Northfield AutoHB-2208, missing weld nutD412Root cause
8D-26-015Bluegrass SeatingBR-3310, rustD571Past due
Recent
  • J. Kim logged clearance on the die card after resharpen
  • M. Reyes burr gauge checks, 21 of 21 recorded
  • L. Hart control plan rev. E released

Emplotec Three other progressive dies were resharpened in the last 60 days without a clearance record. Add them to D7 and schedule checks?

8D-26-017Die maintenance log
Schedule checks

8D-26-017 at validation, with containment results by location and the control plan change linked. Example companies, people and figures.

Questions people ask about the 8D report format

What are the 8 disciplines of an 8D report?

D0 prepare and emergency response, D1 form the team, D2 describe the problem, D3 interim containment, D4 root causes (occurrence and escape), D5 choose and verify permanent corrective actions, D6 implement and validate them, D7 prevent recurrence, and D8 close and recognize the team. D0 was added in Ford's Global 8D.

What is the difference between an 8D and a CAPA?

A CAPA is the quality system's general process for corrective and preventive action. An 8D is one structured, team-based way of doing the corrective action, used mostly for customer complaints. Many companies open a CAPA and attach the 8D as its investigation.

How long should an 8D take?

Customers set their own deadlines. A common pattern is containment (D3) within 24 to 48 hours, root cause and planned actions (D4 and D5) within a couple of weeks, and closure after validation. Use your customer's requirements manual.

What is an escape point in 8D?

The point in the process where the defect should have been detected but wasn't. The 8D finds the root cause of the escape as well as of the occurrence, so the controls are fixed along with the process.

Is 8D required by IATF 16949?

IATF 16949 doesn't name 8D, but clause 10.2.3 requires a documented problem-solving process covering containment, root cause analysis, systemic corrective actions and verification of their effectiveness. Many automotive customers require the 8D format in their supplier manuals.

How do you validate an 8D corrective action?

Compare the defect rate before and after over an agreed period. In this template's example, customer defects fell from 437.5 per million (42 in 96,000) to 0 in 104,000 parts over three months, and the customer accepted the 8D.

Sources

  1. ASQ: Eight disciplines (8D) problem solvinghttps://asq.org/quality-resources/eight-disciplines-8d
  2. IATF: IATF 16949:2016 and sanctioned interpretationshttps://www.iatfglobaloversight.org/iatf-169492016/about/
  3. AIAG: CQI-20 Effective Problem Solvinghttps://www.aiag.org/quality/automotive-core-tools

Stop typing 8D reports by hand.

Tell us how your business runs. We'll show you Emplotec raising this from the work itself, on your own numbers, and reply within one working day.

WhatsApp